How Storage Architecture Improves GPU Cloud Performance

← Back to blog

The GPU cluster is online. A customer starts training a model, and the first run goes well.

Then another tenant begins loading a dataset. A checkpoint write starts. An inference deployment pulls model files from the same storage infrastructure.

The original training job slows down.

For the platform team, adding GPUs would not resolve the immediate problem. They first need to understand how data moves through the service and where that movement breaks down under concurrent demand.

In our previous article, we explored six storage challenges in a GPU cloud. Here, we look at the architectural decisions that address them, and how TuringData’s storage and KV cache solutions fit into that design.

1. Keep data delivery moving with parallel I/O and distributed metadata

When training workers wait for data, the storage architecture needs to handle both the volume of information and the number of requests.

Those are different demands. Reading large training files consumes bandwidth. Opening millions of smaller files puts pressure on metadata operations. Writing checkpoints introduces bursts of traffic that may overlap with both.

A distributed architecture spreads data access and metadata processing across storage nodes. Parallel I/O allows multiple workers to access data concurrently, helping the system serve a growing workload without concentrating every request on one processing point.

TuringData Platform provides high-performance storage software for training and inference. TuringData Flash packages that software with validated NVMe hardware in an integrated appliance. Its distributed metadata and parallel I/O capabilities address workloads involving large datasets and many files.

For the operator, the intended improvement is practical: less time waiting for training data, faster model loading, and shorter storage operations during checkpoint saves and recovery.

As one benchmark reference, TuringData achieves 541.5 GiB/s of 3D U-Net read bandwidth from three storage nodes in MLPerf Storage v3.0.

2. Make shared storage manageable with tenant resource controls

Now consider the customer whose training job slows down when another tenant writes a checkpoint.

A shared cluster needs policies that govern how customers consume its resources. Otherwise, a workload that performs well alone may become unpredictable as the service fills up.

TuringData Platform supports directory-based quotas and quality-of-service controls. These give operators mechanisms to manage storage consumption and I/O allocation within a shared cluster.

An operator can use these controls when designing service tiers, reserving headroom, and managing competing workloads.

3. Design the network as part of the storage path

Fast storage devices cannot compensate for a congested path between the application and its data.

The design needs to account for client connectivity, switch capacity, traffic distribution and simultaneous access from many GPU servers.

TuringData Platform supports RDMA networking over InfiniBand and RoCE. Its Elastic Data Network supports multiple network planes within a storage cluster, allowing the architecture to accommodate training and inference connectivity requirements.

TuringData Flash also supports NVIDIA GPUDirect Storage. In compatible deployments, GPUDirect Storage provides a direct transfer path between storage and GPU memory that avoids an intermediate CPU bounce buffer.

These capabilities address different parts of data movement. Their benefit depends on the application path and the surrounding infrastructure.

4. Place data according to its use

After several months, the provider has accumulated training datasets, checkpoints, model versions and experiment outputs. Some are accessed constantly. Others remain available for occasional recovery or future reuse.

Treating every byte as equally performance-sensitive can make storage expensive to expand. A tiered architecture separates the needs of active workloads from those of longer-term retention.

TuringData Platform’s Smart Tiering moves cold data to object storage while retaining hot data on NVMe. File-and-object integration also supports movement between existing data repositories and the active storage environment. TuringData Flash’s Smart DataLoad connects object storage and file-system workflows. This gives operators options for matching data placement to access requirements.

5. Extend inference cache capacity and enable context reuse

An inference customer presents a different challenge.

Their application repeatedly processes long documents or growing conversations. Useful KV cache is evicted from GPU memory, and later requests repeat work that has already been performed.

Two architectural capabilities can help: retaining cache across memory and storage tiers, and making reusable cache accessible across serving nodes.

TuringData Cache Fabric is software that coordinates KV cache across GPU HBM, host DRAM and local NVMe. It retains computed cache outside GPU memory and retrieves matching prefixes when subsequent requests can reuse them. It can begin with local server resources, without a separate cache appliance.

When reuse needs to span participating inference nodes, TuringData ContextCube provides a shared, persistent KV cache appliance. Nodes retrieve matching cached prefixes over RDMA through compatible integrations, including TuringData Cache Fabric.

The opportunity is to reduce repeated prefill computation. Prefix caching does not directly eliminate the work required to generate each new output token.

Actual gains depend on matching prefixes, compatible model and cache settings, retrieval speed, request placement and tenant access boundaries.

These are independent deployment choices. TuringData ContextCube does not require TuringData Platform, and a storage deployment does not require either KV cache product.

6. Expand storage around the next phase of demand

The next GPU deployment brings additional customers and different workloads.

Storage planning needs to account for the resulting bandwidth, metadata and concurrency requirements—not simply additional capacity.

TuringData Platform and TuringData Flash support three-node starting configurations and scale-out expansion. The software deployment offers infrastructure choice; the appliance combines the software and validated hardware. That gives providers a starting point from which to plan growth.

Turn the architecture into a measurable evaluation

Return to the training job that slowed down as the cloud became busier.

The provider now has several possible interventions: distribute I/O, adjust tenant policies, improve the network path, change data placement, or address inference cache reuse separately.

The next step is to test the intervention against the original customer problem.

Customer problemWhat to measure
Training waits for dataData-loading time and training step time
Checkpoints interrupt progressSave duration and successful recovery time
Tenants interfere with one anotherPer-tenant latency and throughput under competing load
Inference repeats context processingCache hit rate, retrieval overhead and time to first token
Data retention becomes expensiveTotal storage cost and retrieval time
Expansion affects running jobsApplication performance during growth and redistribution

A focused proof of concept connects architecture decisions to service outcomes. It also establishes where a change helps and where another part of the infrastructure remains the constraint.

Share your workloads, bottlenecks and growth plans with TuringData. Together, we can define an architecture and a proof of concept around the improvements your GPU cloud needs.

Find out how much GPU utilization you're leaving on the table. Schedule a free 30-minute architecture review with our experts.